APC Magnum VS 50 w/SNMP Composant de commutation - Noir caractéristiques

500W, 88-264V, 5.5A, LED, 438x330x133mm, 9.5kg, 3U

APC Magnum VS 50 w/SNMP, Alimentation électrique, Noir, Alarme, Réseau, Statut, Sur-courant, CE, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, UL 1950, 500 W

Magnum VS 50 w/SNMP -- GMT FUSE DISTRIBUTION
Reliable and flexible DC power solutions for customer premise broadband, low power wireless and other telecommunication applications.
Includes : Rack Mounting Brackets , User Manual

- Battery voltage temperature compensation
Automatic battery float voltage temperature compensation extends battery life and performance
- Cable Entry
Configurable for either top or bottom cable entry.
- Dry Contact inputs
User assignable inputs allow other equipment alarms to be monitored through the power system controller
- Integral low voltage disconnect
Automatic LVD function extends battery life by preventing damage caused by deep discharge.

Manageability
- LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Availability
- Internal Protection
Integral over-current protection devices protect the system against overload faults.
- Battery voltage temperature compensation
Automatic battery float voltage temperature compensation extends battery life and performance
- Extendable Run Time
Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.

Serviceability
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Front Access
Installation and maintenance of all components can be carried out without access to the rear or sides of the cabinet.
- Automatic restart of loads after UPS shutdown